BCS-900 Series

The BCS-900 Series is the current BioLogic premium battery cycler range and the successor to the BCS-800. It offers eight channels per module, 1 ms acquisition, negative-voltage models, the regenerative BCS-975R and the BT-Lab Suite software.

Key specifications

BCS-905
±150 mA per channel, made for coin cells and other small formats. Also available as the BCS-905/n, which works from -2.5 V to 7.5 V.
BCS-910
±1.5 A per channel for lab-scale research and pilot lines. The BCS-910/n version works from -5 V to 5 V.
BCS-915
±15 A per channel, with channels that can be paralleled for ±30 A, ±60 A or ±120 A when you need more current.
BCS-975R
±75 A per channel for large-format pouch and prismatic cells, up to ±300 A with four channels in parallel. It's regenerative, recovering energy during discharge, and comes complete in a 16U cabinet.
Faster data
acquisition time and time base drop from 2 ms to 1 ms.
Negative voltage
new /n versions of the BCS-905 and BCS-910 go below 0 V, down to -5 V.
More power
the BCS-975R adds ±75 A per channel and regenerative discharge.
New software
BT-Lab® Suite, with BT-Test™ embedded in the instrument and BT-Analysis™ for batch processing, plus REST API, Python and OPC-UA integration options.
Your existing data still counts
BioLogic's BT-Export™ remains compatible with BCS-800 .mpr files, and the BCS-CAL calibration kit covers both series.
BT-Test™
design, run and monitor
BT-Analysis™
batch analysis
After-sales support
troubleshooting, servicing, calibration, spare parts, software updates and warranty claims, working directly with BioLogic when needed.
BCS-905 Channels per module
8
BCS-905 Maximum current per channel
±150 mA
BCS-905 Current ranges
5, from 100 mA down to 10 µA
BCS-905 Current control resolution
down to 0.8 nA
BCS-905 Current measurement resolution
down to 0.2 nA (18 bit)
BCS-905 Current accuracy
0.015% of FSR + 0.05% of setting
BCS-905 Voltage range
0 V to 10 V (BCS-905/n: -2.5 V to 7.5 V)
BCS-905 Voltage control resolution
150 µV
BCS-905 Voltage measurement resolution
40 µV (18 bit)
BCS-905 Voltage accuracy
±0.3 mV + 0.01% of setting
BCS-905 Slew rate
150 kV/s
BCS-905 EIS
optional, 10 kHz to 10 mHz
BCS-905 Acquisition time and time base
1 ms
BCS-905 Height, weight, power
1U, 6.5 kg, 60 W
BCS-910 Channels per module
8
BCS-910 Maximum current per channel
±1.5 A
BCS-910 Current ranges
5, from 1 A down to 0.1 mA
BCS-910 Current control resolution
down to 8 nA
BCS-910 Current measurement resolution
down to 2 nA (18 bit)
BCS-910 Current accuracy
0.015% of FSR + 0.05% of setting (100 mA range); 0.015% of FSR + 0.1% of setting (1 A range)
BCS-910 Voltage range
0 V to 10 V (BCS-910/n: -5 V to 5 V)
BCS-910 Voltage control resolution
150 µV
BCS-910 Voltage measurement resolution
40 µV (18 bit)
BCS-910 Voltage accuracy
±0.3 mV + 0.01% of setting
BCS-910 Slew rate
150 kV/s
BCS-910 EIS
optional, 10 kHz to 10 mHz
BCS-910 Acquisition time and time base
1 ms
BCS-910 Temperature
K-type thermocouple input on each channel, -25 °C to +200 °C, ±2 °C
BCS-910 Height, weight, power
2U, 11 kg, 220 W
BCS-915 Channels per module
8
BCS-915 Maximum current per channel
±15 A; ±30 A, ±60 A or ±120 A with channels in parallel
BCS-915 Current ranges
5, from 10 A down to 1 mA
BCS-915 Current control resolution
down to 80 nA
BCS-915 Current measurement resolution
down to 20 nA (18 bit)
BCS-915 Current accuracy
0.015% of FSR + 0.05% of setting (100 mA range); 0.015% of FSR + 0.1% of setting (1 A range); 0.04% of FSR + 0.3% of setting (10 A range)
BCS-915 Voltage range
0 V to 9 V
BCS-915 Voltage control resolution
150 µV
BCS-915 Voltage measurement resolution
40 µV (18 bit)
BCS-915 Voltage accuracy
±0.3 mV + 0.01% of setting
BCS-915 Slew rate
3 kV/s
BCS-915 EIS
optional, 10 kHz to 10 mHz
BCS-915 Acquisition time and time base
1 ms
BCS-915 Temperature
K-type thermocouple input on each channel, -25 °C to +200 °C, ±2 °C
BCS-915 Height, weight, power
4U, 24.5 kg, 1700 W
Channels
8
BCS-975R Maximum current per channel
±75 A; up to ±300 A with four channels in parallel
BCS-975R Current ranges
3, from 75 A down to 750 mA
BCS-975R Current control resolution
down to 360 nA
BCS-975R Current measurement resolution
down to 89 nA (24 bit)
BCS-975R Voltage range
0 V to 5 V
BCS-975R Voltage control resolution
100 µV
BCS-975R Voltage measurement resolution
0.360 µV (24 bit)
BCS-975R Voltage accuracy
1.5 mV + 0.05% of setting
BCS-975R Slew rate
2.5 kV/s
BCS-975R EIS
optional, 2 kHz to 10 mHz
Acquisition time
1 ms; time base: 5 ms
BCS-975R Temperature
optional auxiliary measurement with the TC-32
Format, weight, power
complete 16U cabinet, 120 kg, 5000 W