In-Situ Raman Spectroelectrochemical Cell (Basic, 3-Electrode), Model: EC-RM1
In-Situ Raman Spectroelectrochemical Cell (Basic, 3-Electrode), Model: EC-RM1 is available from ProDigitek, an Australian supplier, shipped within Australia.
EC-RM1 In-Situ Raman Spectroelectrochemical Cell
A compact three-electrode spectroelectrochemical cell for operando Raman monitoring of electrochemical interfaces.
The EC-RM1 provides direct Raman access to a plate-type working electrode through a quartz optical window while maintaining three-electrode electrochemical control. Its compact single-chamber design supports both static electrolyte filling and external electrolyte circulation, making it suitable for mechanistic studies in electrocatalysis, battery materials, and electrochemical interface research.
Key Features
Direct Interface Observation
Enables direct optical access to a single electrochemical interface for fundamental reaction studies
Minimal System Complexity
Single-chamber configuration provides a simplified reaction environment for baseline mechanistic analysis
Interface Evolution Analysis
Enables investigation of electrode surface reconstruction and interfacial structural changes during electrochemical operation
Technical Specifications
Working electrode area: 1 cm² (customisable)
Optical window diameter: Ø37 mm (effective diameter Ø34 mm)
Chamber structure: Single-chamber
Working electrode: Plate-type electrodes (e.g., Au, Pt, glassy carbon, ITO, FTO, and carbon paper)
Reference electrode: Ag/AgCl or Ag/Ag⁺ electrode
Counter electrode: Platinum wire electrode
Cell body material: PEEK + Ti
Optical window material: Quartz
Cell body dimensions: L70 × W70 × H19 mm
Instrument Compatibility
Raman System Compatibility
Compatible with commercial Raman microscope systems, including Renishaw (inVia Qontor), HORIBA (LabRAM HR Evolution, iHR550), and Ocean Optical Instruments (HRS-5A)
Potentiostat Compatibility
Compatible with commercial three-electrode electrochemical workstations, including CH Instruments (CHI660E, CHI760E, CHI1140C), Bio-Logic (VMP3), and Corrtest Instruments (CS350M)
Published Application Example
In-situ Raman Monitoring of Glycerol Electrooxidation
Demonstrated EC-RM1 Capabilities
Simultaneous Raman and electrochemical measurements
Continuous monitoring under an applied potential
Compatibility with catalyst-coated carbon paper
Additional Published Applications
Chen, W. et al. ACS Sustainable Chem. Eng. 2025, 13, 11607-11616.
Lv, H. et al. Nat. Commun. 2023, 14, 3117.
Typical Uses
Electrochemical and battery research laboratories
In-situ and operando characterisation studies