In Situ Raman Spectroelectrochemical Cell (3-Electrode), Model: EC-RM3
In Situ Raman Spectroelectrochemical Cell (3-Electrode), Model: EC-RM3 is available from ProDigitek, an Australian supplier, shipped within Australia.
EC-RM3 In Situ Raman Spectroelectrochemical Cell
A three-chamber gas-diffusion spectroelectrochemical cell for operando Raman monitoring of gas-fed electrochemical interfaces.
The EC-RM3 combines direct Raman access with a membrane-separated, three-chamber configuration for gas-fed electrochemical studies. A dedicated gas channel delivers reactant gas to the working electrode in the cathode chamber, enabling operando investigation of gas-liquid-solid interfaces under three-electrode control.
Key Features
Gas-Fed Interface Monitoring
Provides direct Raman access to the gas-diffusion cathode interface under a continuous supply of reactant gas.
Membrane-Separated Reaction Control
Separates the cathodic and anodic compartments to reduce product crossover and minimise interference between electrode reactions.
Operando Interfacial Analysis
Enables real-time investigation of reaction intermediates, catalyst evolution, and gas-liquid-solid interfacial processes.
Technical Specifications
Working electrode area: 1 cm² (customisable)
Optical window diameter: Ø37 mm (effective diameter Ø34 mm)
Chamber structure: Three-chamber
Working electrode: Sheet-type gas-diffusion electrode (e.g., Au, Pt, glassy carbon, ITO, and FTO)
Reference electrode: Ag/AgCl or Ag/Ag⁺ electrode
Counter electrode: Platinum wire electrode or graphite rod electrode
Cell body materials: PEEK + Ti
Optical window material: Quartz
Cell body dimensions: L99 × W70 × H25 mm
Instrument Compatibility
Raman System Compatibility
Compatible with commercial Raman microscope systems, including Renishaw (inVia Qontor), HORIBA (LabRAM HR Evolution and iHR550), and Ocean Optical Instruments (HRS-5A).
Potentiostat Compatibility
Compatible with commercial three-electrode electrochemical workstations, including CH Instruments (CHI660E, CHI760E, and CHI1140C), Bio-Logic (VMP3), and Corrtest Instruments (CS350M).
Published Application Example
In Situ SERS Monitoring of CO₂ Electroreduction
Demonstrated EC-RM3 Capabilities
Operando monitoring in a gas-fed flow-cell configuration
Compatibility with catalyst-loaded carbon-paper electrodes
Tracking of reaction intermediates and catalyst-state evolution
Additional Published Applications
Chang, B. et al., Chemical Engineering Journal, 2024, 496, 153993.
Jia, G. et al., Nano Research, 2025, 18, 94907265.
Typical Uses
Electrochemical and battery research laboratories
In-situ and operando characterisation studies