top of page

Gas Diffusion Electrochemical Cell (3-Electrode), Model: EC-GDE6

Gas Diffusion Electrochemical Cell (3-Electrode), Model: EC-GDE6 is available from ProDigitek, an Australian supplier, shipped within Australia.

EC-GDE6 Gas Diffusion Electrochemical Cell

An ultra-short-gap, three-electrode GDE flow cell for gas-fed electrochemical testing at medium-to-high current densities and long-duration stability studies.

Key Features

0.4 mm Ultra-Short Electrode Gap

The redesigned catholyte pathway minimises the distance between the working and counter electrodes.

Serpentine Gas Flow Field

Designed for Demanding Operation

Supports medium-to-high current densities and extended stability testing.

Typical Applications

Gas-Fed Electrocatalysis

Evaluation of GDE-based reactions under controlled gas and electrolyte flow.

Medium-to-High Current Testing

Investigation of electrode performance under demanding current-density conditions.

Flow-Field Evaluation

Assessment of serpentine and customised gas-distribution patterns.

Long-Duration Stability Studies

Monitoring electrode and cell performance during extended electrolysis.

Technical Specifications

Chamber structure: Three-chamber

Electrode system: Three-electrode

Anode-cathode gap: 0.4 mm

Active area: 1 or 4 cm² (10 x 10 mm or 20 x 20 mm, customisable)

Working electrode: Sheet-type gas diffusion electrode (customer-supplied)

Reference electrode: Rod-type Ag/AgCl electrode

Counter electrode: Sheet-type IrO₂ mesh electrode (customer-supplied)

Cell body material: Ti + PEEK

Gas flow field: Serpentine (customisable)

Instrument Compatibility

Gas and Electrolyte Flow Compatibility

Compatible with regulated gas supplies and electrolyte-circulation systems equipped with mass flow controllers, gas flow meters, peristaltic pumps and gas-liquid mixing pumps.

Potentiostat Compatibility

Compatible with commercial potentiostats supporting three-electrode measurements, including CH Instruments (CHI660E, CHI760E, CHI1140C), Bio-Logic (VMP3), Corrtest Instruments (CS350M), Ivium Technologies (CompactStat.e20250), and Metrohm Autolab (PGSTAT204).

Related Published Application

Effects of Catholyte Flow Design on CO₂ Electrolysis

Filippi et al. evaluated four 3D-printed PEEK catholyte compartments, Linear-wide, Shifted, Serpentine and Linear, in a 5 cm² CO₂ flow electrolyzer. The system incorporated a PTFE/CuO gas diffusion cathode, an Ag/AgCl reference electrode, a Ni-foam anode and an anion-exchange membrane. All configurations used a gasket-defined 0.2 mm catholyte gap and were tested from 50 to 700 mA cm⁻². Experiments and CFD simulations demonstrated that catholyte hydrodynamics govern bubble removal, local pH and product selectivity, with balanced flow velocities of 0.01-0.1 m s⁻¹ favouring C₂+ production.

Demonstrated EC-GDE6 Capabilities

Supports CO₂ electroreduction at 50-700 mA cm⁻²

Demonstrates thin-gap GDE testing in a three-electrode configuration

Links catholyte flow and bubble removal to activity and product selectivity

Application Studies

Application studies using this model are currently underway.

Note: The referenced study used a custom-built 5 cm² CO₂ flow electrolyzer with a 0.2 mm catholyte gap and a configuration comparable to the EC-GDE6 and is included solely as a related application example.

Typical Uses

Electrochemical and battery research laboratories

In-situ and operando characterisation studies

Gas Diffusion Electrochemical Cell (3-Electrode), Model: EC-GDE6

$5,761.20Price
Quantity
    bottom of page