Gas Diffusion Electrochemical Cell (3-Electrode), Model: EC-GDE6
Gas Diffusion Electrochemical Cell (3-Electrode), Model: EC-GDE6 is available from ProDigitek, an Australian supplier, shipped within Australia.
EC-GDE6 Gas Diffusion Electrochemical Cell
An ultra-short-gap, three-electrode GDE flow cell for gas-fed electrochemical testing at medium-to-high current densities and long-duration stability studies.
Key Features
0.4 mm Ultra-Short Electrode Gap
The redesigned catholyte pathway minimises the distance between the working and counter electrodes.
Serpentine Gas Flow Field
Designed for Demanding Operation
Supports medium-to-high current densities and extended stability testing.
Typical Applications
Gas-Fed Electrocatalysis
Evaluation of GDE-based reactions under controlled gas and electrolyte flow.
Medium-to-High Current Testing
Investigation of electrode performance under demanding current-density conditions.
Flow-Field Evaluation
Assessment of serpentine and customised gas-distribution patterns.
Long-Duration Stability Studies
Monitoring electrode and cell performance during extended electrolysis.
Technical Specifications
Chamber structure: Three-chamber
Electrode system: Three-electrode
Anode-cathode gap: 0.4 mm
Active area: 1 or 4 cm² (10 x 10 mm or 20 x 20 mm, customisable)
Working electrode: Sheet-type gas diffusion electrode (customer-supplied)
Reference electrode: Rod-type Ag/AgCl electrode
Counter electrode: Sheet-type IrO₂ mesh electrode (customer-supplied)
Cell body material: Ti + PEEK
Gas flow field: Serpentine (customisable)
Instrument Compatibility
Gas and Electrolyte Flow Compatibility
Compatible with regulated gas supplies and electrolyte-circulation systems equipped with mass flow controllers, gas flow meters, peristaltic pumps and gas-liquid mixing pumps.
Potentiostat Compatibility
Compatible with commercial potentiostats supporting three-electrode measurements, including CH Instruments (CHI660E, CHI760E, CHI1140C), Bio-Logic (VMP3), Corrtest Instruments (CS350M), Ivium Technologies (CompactStat.e20250), and Metrohm Autolab (PGSTAT204).
Related Published Application
Effects of Catholyte Flow Design on CO₂ Electrolysis
Filippi et al. evaluated four 3D-printed PEEK catholyte compartments, Linear-wide, Shifted, Serpentine and Linear, in a 5 cm² CO₂ flow electrolyzer. The system incorporated a PTFE/CuO gas diffusion cathode, an Ag/AgCl reference electrode, a Ni-foam anode and an anion-exchange membrane. All configurations used a gasket-defined 0.2 mm catholyte gap and were tested from 50 to 700 mA cm⁻². Experiments and CFD simulations demonstrated that catholyte hydrodynamics govern bubble removal, local pH and product selectivity, with balanced flow velocities of 0.01-0.1 m s⁻¹ favouring C₂+ production.
Demonstrated EC-GDE6 Capabilities
Supports CO₂ electroreduction at 50-700 mA cm⁻²
Demonstrates thin-gap GDE testing in a three-electrode configuration
Links catholyte flow and bubble removal to activity and product selectivity
Application Studies
Application studies using this model are currently underway.
Note: The referenced study used a custom-built 5 cm² CO₂ flow electrolyzer with a 0.2 mm catholyte gap and a configuration comparable to the EC-GDE6 and is included solely as a related application example.
Typical Uses
Electrochemical and battery research laboratories
In-situ and operando characterisation studies