top of page

CT PCB Series

The CT PCB Series brings 0-FLUCS DC current transducer technology from ELS Instruments (formerly CAEN ELS) to a board-mount package. Designers can place precise, galvanically isolated current measurement directly on a printed circuit board, avoiding bulky external sensors in power converters, battery management systems and laboratory instruments. Three primary current ratings are available: ±13 A, ±26 A and ±52 A, all bipolar. Transformation ratios are 1:250, 1:500 or 1:1000, and small signal bandwidth is 200 kHz or 500 kHz depending on the version. Typical accuracy is better than 30 ppm of full scale for current-output models and better than 0.25 % of full scale for voltage-output models. The transducers run from a ±15 V supply and mount via a 16-pin through-hole footprint. Compared with shunts and Hall sensors, this approach offers much lower drift and better linearity, which matters in precision supplies and metrology. Electronics designers, OEMs and research engineers are the core audience. If you are designing a board, ProDigitek can supply samples and datasheets. Contact us to talk part numbers.

CT PCB Series

Key specifications

Maximum DC primary current
±13 A, ±26 A or ±52 A
Current polarity
Bipolar
Transformation ratio
1:250, 1:500 or 1:1000
Small signal bandwidth
200 kHz or 500 kHz
Accuracy (typ.)
< 30 ppm/FS (current output), < 0.25 %/FS (voltage output)
Supply voltage
±15 V
Mounting
16-pin through-hole PCB
bottom of page