CT-3000
The CT-3000 is the highest rated 0-FLUCS DC current transducer listed by ELS Instruments (formerly CAEN ELS), rated to measure ±3000 A bipolar. It shares the 67 mm aperture and 24 V supply of the CT-2000, extending isolated precision measurement to the very high currents found in heavy industry and large research installations. Transformation ratio is 1:2000, so full scale equals 1.5 A on the current output. Bandwidth is greater than 100 kHz, and equivalent input noise is below 2 ppm of full scale at 200 Hz. Temperature drift is under 0.5 ppm/K for current output and 3 ppm/K for voltage output. Applications include electrowinning and refining, hydrogen electrolyser plants, high current DC bus monitoring, superconducting cable testing and calibration of large shunts. Precise measurement at 3 kA helps verify process efficiency and protect costly equipment. Installation needs some planning around busbar routing and supply wiring, and ProDigitek can carry out on-site installation on the east coast. Contact us to discuss your CT-3000 application.

Key specifications
Maximum DC primary current | ±3000 A |
Current polarity | Bipolar |
Transformation ratio | 1:2000 |
Small signal bandwidth (±3 dB) | > 100 kHz |
Equivalent input noise | < 2 ppm/FS @ 200 Hz |
Temperature coefficient | < 0.5 ppm/K (current output), < 3 ppm/K (voltage output) |
Primary conductor hole | 67 mm |
Supply voltage | 24 V |