CT-2000
The CT-2000 from ELS Instruments (formerly CAEN ELS) moves the 0-FLUCS DCCT range into multi-kiloamp territory, measuring bipolar currents up to ±2000 A. A large 67 mm primary conductor hole accommodates substantial busbars, and the sensor runs from a single 24 V supply instead of the ±15 V used by smaller models. The transformation ratio is 1:2000, giving 1 A at full scale on the current output. Small signal bandwidth exceeds 100 kHz, and input noise remains under 2.5 ppm/FS at 200 Hz. Drift is specified at less than 0.5 ppm/K with current output, rising to 3 ppm/K with voltage output. Uses include electrolytic and smelting processes, high power rectifiers, superconducting magnet supplies, grid-scale storage and traction systems. In Australia, that covers mining and mineral processing, renewable energy and hydrogen projects as well as research facilities. Accurate measurement at this level often justifies itself quickly through better efficiency data. Both output versions are offered. Send ProDigitek your conductor dimensions and we'll recommend a configuration and price.

Key specifications
Maximum DC primary current | ±2000 A |
Current polarity | Bipolar |
Transformation ratio | 1:2000 |
Small signal bandwidth (±3 dB) | > 100 kHz |
Equivalent input noise | < 2.5 ppm/FS @ 200 Hz |
Temperature coefficient | < 0.5 ppm/K (current output), < 3 ppm/K (voltage output) |
Primary conductor hole | 67 mm |
Supply voltage | 24 V |