CT-150
Sitting between the 100 A and 200 A models, the CT-150 from ELS Instruments (formerly CAEN ELS) is a 0-FLUCS DC current transducer rated for bipolar currents up to ±150 A. It suits applications that slightly exceed 100 A, such as mid-size battery packs, electrolyser stacks and laboratory magnets, without stepping up to a larger, heavier sensor. Its 1:1500 transformation ratio gives 100 mA of output current at full scale. Small signal bandwidth (±3 dB) exceeds 300 kHz in the current-output version and 200 kHz in the voltage-output version. Input-referred noise stays below 1 ppm/FS at 200 Hz, and thermal drift is less than 0.5 ppm/°C (current-output model) or 2 ppm/°C (voltage-output model), keeping readings steady through daily laboratory temperature swings. The 16 mm aperture accepts a cable or bar, and the transducer runs from ±15 V. Both output styles are offered, so it can feed either a precision resistor or a direct voltage input. Ask ProDigitek about CT-150 lead times and pricing for your project.

Key specifications
Maximum DC primary current | ±150 A |
Current polarity | Bipolar |
Transformation ratio | 1:1500 |
Small signal bandwidth (±3 dB) | > 300 kHz (current output), > 200 kHz (voltage output) |
Equivalent input noise | < 1 ppm/FS @ 200 Hz |
Temperature coefficient | < 0.5 ppm/°C (current output), < 2 ppm/°C (voltage output) |
Primary conductor hole | 16 mm |
Supply voltage | ±15 V |